Sample Collection   Sample Preparation   Sample Extraction   qPCR                          

Sample CollectionSample collection kit

PCR detection with 3DMed Sample Transport Medium(Extraction Free)

Features

One step operation

· Inactivation together with lysis without adding nucleic acid releasing agent

Good stability

· Stored steadily at room temperature for 1 day after sampling

Time saving reduces labor

· The lysis products can be directly used in qPCR

High sensitivity

· No washing and elution No loss of nucleic acid

Product Specifications

Applicable Specimens Swab
Tube volume 10ml/1.5ml
Liquid loading volume 1ml/0.5ml
Packaging 50 PCS/box
Accessory NP swabs included
 

Sample PreparationANDiS3100

ANDiS3100 Sample Preparation Workstation (Automation with flexibility) can perform de-capping/re-capping of STM tubes, tube-to-plate liquid transfer, barcode scanning and information tracking.

 

Features

Flexible through-put

16 - 96 samples/batch , up to 3,800 samples/day

Data tracking

Whole process traceability- From sample ID to extraction ID, qPCR well ID and final result

Bio-safety

HEPA / UV LAMP / Negative Pressure(-2 to -5 Pa)

Stable and reliable

 

 

Product Specifications

Item Value
Volume range 10-1000µL
Throughput 96 samples
Sample type Sampling tube of 2ml/5ml/10ml size
Operation interface Full color large LED screen, English/Chinese display, touch screen operation
UV Enabled
Sampling time 22 seconds / tube for the whole sampling workflow
Input Voltage AC100-240V, 50/60Hz
Power 220W
Size 1100mm×680mm×763mm
Weight 150KG

Your flexible partners of pre-processing extraction

 

Sample ExtractionANDiS 350

ANDiS 350 Automated Nucleic Acid Extraction System enables fully automated extraction of highly pure nucleic acids with magnetic bead-based technology. Extracted nucleic acids can be used for molecular testing with a variety of techniques such as PCR, qPCR, NGS library preparation, and microarray.

Features

Easy-to-use

· 7-inch color touch screen display, built-in computer with Android OS;
· Pre-loaded reagents & fully automated sample processing, minimal hands-on time;
· USB supported for system upgrade and program import;

Small-in-size

· Approximately 15.8 in x 15.8 in x 17.8 in in size, easily fits in any biosafety cabinet, easily transported;

Ultra-efficient and rapid

· >95% recovery rate of magnetic beads, ultra-high extraction efficiency;
· Turnaround time of 30~60 minutes (reagent dependent) ;

Robust and reliable

· Built-in UV lamp for preventing contamination, <3% CV for technical replicates;

Readily Adaptable

· Compatible with different magnetic bead-based nucleic acid extraction reagents;
· Memory for storing up to 500 programs;
· Optimized protocols for each sample type;

Product Specifications

Reaction Volume 30μl-1000μl
Sample Throughput 16/32
Magnetic beads recovery rate >95%
Extraction variation CV<3%
Heating temperature Adjustable from room temperature to 115℃/240℉
Reagent type Magnetic bead-based open source reagents
Extraction time 30-60 mins (reagent dependent)
Well plate 96deep well plate
Operation system Android system in Chinese with touch screen
Memory storage Up to 500 programs
Program management Add,edit,and delete programs
UV lamp Yes
Light Yes
Device size 15.8 in. x 15.8 in x 17.8 in
Device weight 35kg

Related Documents

  • Materials

    ANDiS 350 brochure

    on:2020-05-05 amount:220

  • Videos

    ANDiS 350 brochure

    on:2020-05-05 amount:220

 

ANDiS380 extraction kit

ANDiS Viral RNA Auto Extraction & Purification Kit utilize magnetic beads-based technology for automated isolation and purification of RNA from biological samples. The product is intended to be used by professional users that are trained in molecular biological techniques. The ANDiS Viral RNA Auto Extraction & Purification Kit is for in vitro diagnostic use.

Features

Reliable

· Average Ct of the sample extracted by 3DMed is very close to ThermoFisher.
·CV values of Ct value < 2% by means of qPCR detection.

Efficient

· Process 96 samples in ≤ 15mins by “3DMed-KF96” program.
·2X efficiency than general.

Convenient

· Prifilled plates,less labor needs.

Economical

· 60% Cost reduction

Product Specifications

Volume of Sample 200-400µL
Elution Volume 50µL
Technology Magnetic beads based
Operation Fully automated
Turn -around-time Less than 15 mins
Compatible instrument model KingFisher Flex & Allsheng Auto-pure96
Sample Throughput 96
 

ANDiS Viral RNA Auto Extraction & Purification Kit

ANDiS Viral RNA Auto Extraction & Purification Kit is intended to be used with ANDiS 350 Automated Nucleic Acids Extraction System for high quality nucleic acids extraction and purification from serum, plasma, swab, urine and other types of clinical specimen.

Features

Equivalent extraction efficiency

· Four samples* were extracted using ANDiS Viral RNA Kit and competitor's manual Kitwith 4 replicates, and tested by ANDiS SARS-CoV-2 RT-qPCR Detection Kit.

Intra-assay reproducibility

· One operator performed 3 individual runs on the same instrument, on 3 different days. The replicates in each run were 16 for each sample*.

Inter-lot precision

· For Inter-lot precision study, 3 lots of ANDIS Viral RNA Kits were used. The replicates in each run were 16 for each sample*.

Product Specifications

Applicable Specimens Swab, Serum, Plasma, Urine etc
Volume of Sample 200 μL as recommended sample addition
Elution Volume 100 μL
Technology Magnetic beads based
Operation Automated
Turn-around-time 20 min
Linear Range 101 -108 RNA copies/mL
 

ANDiS Viral Nucleic Acid Auto Extraction & Purification Pooling Kit

This kit is intended to be used with ANDiS 350 Automated Nucleic Acids Extraction System for high quality nucleic acids extraction and purification from serum, plasma, swab, urine and other types of clinical specimen.

Features

No Discounted Detection Sensitivity

· Through optimizing sample input and elution volume, 3DMed’s pooling kit provides the undiluted viral RNA extracted from each pooled sample (10 in 1 at most) to ensure detection sensitivity in the following step.
· As shown on the right, qPCR analysis of viral RNA amplification revealed no significant difference between pooling test (1positive+9 negative samples) and single sample test in Ct values.

Improve 5X Extraction Efficiency

· ANDiS Viral RNA Auto Extraction & Purif ication Kit Extraction of 32 samples in 20 min.
· ANDiS Viral Nucleic Acid Auto Extraction & Purification Pooling Kit Extraction of 320 samples in 35 min.

Up to 80% Decrease of Detection Cost

· 1sample --> 1extraction --> 1PCR
· Up to 10 samples --> 1extraction --> 1PCR
Additional single tests shall be applied to the pooled samples with positive results. The optimum pooling ratio shall be decided according to the local COVID-19 prevalence.

Product Specifications

Applicable Specimens Swab
Volume of Sample 150 μL per sample & 10 pooled samples at most
Elution Volume 75 μL
Technology Magnetic beads based
Operation Automated
Turn-around-time 35 min
Linear Range 101 -108 RNA copies/mL
 

qPCR-ReagentANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit V4.1

ANDiSFASTSARS-CoV-2RT-qPCR DetectionKit V4.1 is intended to detect the Orf1ab, and N genes of the SARS-Cov-2 virus, the LoD is 200 copies/mL. The RT-qPCR reaction takes about 30min when selecting the "fast mode" on ABI QuantStudio 5.

Features

Whole Process Control

· The exogenous internal control can monitor the nucleic acid extraction and RT-PCR processes, therefore is suitable for controlling the workflow of environmental sample detection to ensure the accuracy of the detection results.

30min qPCR Runtime

· The assay is a one-step real-time RT-qPCR that takes about 30min when selecting the“fast mode” on ABI QuantStudio5. The turnaround time for the entire workflow would be as short as 1.5 hours.

Product Specifications

Target Regions ORF1ab and N genes
Detection Technology One-step real-time RT-qPCR
Fluorescent Channel FAM, ROX, VIC
Limit of Detection 200 copies/mL
PCR Runtime 30~50minutes on common qPCR instruments
Reaction Volume 25μL(12.5μL Master Mix+ 12.5μL RNA)
Compatible Instruments(validated) ABI QuantStudio 5; ABI 7500; Bio-Rad CFX96 Deep Well; Bioer QuantGene 9600,etc.
 

ANDiS FAST SARS-CoV-2 RT-qPCR Detection Kit V5.1

ANDiSFASTSARS-CoV-2RT-qPCR DetectionKit V5.1 is intended to detect the Orf1ab, N and E genes of the SARS-Cov-2 virus, the LoD is 200 copies/mL. The RT-qPCR reaction takes about 30min when selecting the "fast mode" on ABI QuantStudio 5.

Features

Easy Operation

· This kit uses the human RNaseP gene as the internal control(IC), therefore eliminates one pipetting step during sample preparation. Also,the endogenous IC is suitable for monitoring the entire workflow from sampling to detection.

Fast Detection

· The assay is a one-step real-time RT-qPCR that has been specially optimized to take only around 30mins when selecting the“fast mode” on ABI QuantStudio5. The turn around time for the entire workflow would be as short as 1 hour.

High Accuracy

· Clinical evaluation of 236 specimens demonstrated that,the positive percent agreement(PPA) is 99.18% and the negative percent agreement(NPA) is 100%. In addition, the validated limit of detection(LoD) is 200 copies/mL.

Wide Compatibility

· The kit has been validated on a broad range of common instruments, including the ABI7500, QuantStudio5, Bio-Rad CFX96 Deep Well, and Bioer QuantGene 9600. The 20μL reaction volume is readily adaptable to 384-well format.

Product Specifications

Target Regions ORF1ab, N and E gene
Detection Technology One-step real-time RT-qPCR
Fluorescent Channel FAM, ROX, VIC, CY5
Limit of Detection 200 copies/mL
PCR Runtime 30~50minutes on common qPCR instruments
Reaction Volume 20μL(10μL Master Mix+ 10μL RNA)
Compatible Instruments(validated) ABI QuantStudio 5; ABI 7500; Bio-Rad CFX96 Deep Well; Bioer QuantGene 9600,etc.
 

3DMed SARS-CoV-2 Mutations Detection Kit

According to the WHO Weekly epidemiological update on COVID-19, the B.1..7(UK), B.1.351(South Africa), P.1(Brazil) are listed as the top variants of concern. Among them, B.1.1.7, was about 70% more transmissible than the original strain; These variants also accounts for the majority of the mutant strains worldwide. E484K and N501Y are the key mutations that help to identify the B.1.1.7, B.1.351, P.1 strains.

 

Features

Intended Use 1

· The kit is designed for the simultaneous detection of the SARS-CoV-2 N gene, N501Y and E484K mutations on the S gene.

Intended Use 2

· The kit can be used to re-confirm a previously diagnosed SARS-CoV-2 positive case, and also helps to determine if the specimen carry B.1.1.7, B.1.351, B.1.525 or P.1 mutant strains.

Product Specifications

Target Regions N501Y, E484K, RNaseP and N gene
Applicable specimen type oropharyngeal swab or nasopharungeal swab
Fluorescent Channel FAM, ROX, VIC, CY5
Limit of Detection 400 copies/mL
Package 100 tests
Compatible Instruments(validated) ABI QuantStudioTM 5; ABI 7500; Bio-Rad CFX96 Deep Well Dx system; SLAN-96P
contact information